System information

© 2006 Cisco Systems, Inc. All rights reserved. Cisco Confidential Presentation_ID Kirkpatrick 092509
24
Step 2: ICIM In ICIM Out Cable
Connections
1. Connect the serial extension cable (CIFA 144856) from the
ICIM OUT of the chassis containing the ICIM2-XD to the
ICIM IN connector of the second chassis.
2. Connect a serial extension cable from the ICIM OUT of the
second chassis to the ICIM IN of the third chassis, if
installed, third chassis to fourth etc.
3. Change the chassis ID numbers as needed to give each
chassis an appropriate unique ID number. See To Change
the Chassis ID Number below for further details and
cautions.
4. The ICIM OUT port of the last chassis in the daisy-chain
must be terminated with an ICIM OUT terminator, part
number 4013014, which ships with the ICIM2-XD.
TP477
ICIM Out
Terminator
Serial
Extension
Cable
Chassis with
ICIM
Chassis
Chassis
ICIM Out
EM In
ICIM Out
ICIM Out
ICIM In
ICIM In
Chassis
ICIM Out
ICIM In
Serial
Extension
Cable
Serial
Extension
Cable