Specifications
1-44 Transmitters 4000326 Rev A
Monitor Status Parameters,
Continued
STATUS Screen Description
The first STATUS screen is called the Summary STATUS screen, and it provides the
following transmitter information:
• Laser power in dBm
• Laser bias current in mA
• SMC ID of the transmitter
When in the summary STATUS screen, press the Select
key on the transmitter
to rotate through the remaining parameters.
Status Parameters
The following table describes each status parameter.
Note: The Continuous Wave Mode parameter applies only to the Model 6475Q
Forward Transmitter.
Parameter Meaning Description
Summary
STATUS
Screen:
• Power
Laser power
• Bias
Laser bias current in mA
• ID
Module summary
Unit SMC ID number
Power Laser power Laser power in dBm
Bias Laser bias Laser bias current in mA
Ltemp Laser temperature Laser temperature in degrees Celsius
RFlvl RF level RF input status
CW Mode
Continuous wave
operation
Continuous wave operation status
Rel RFdrv RF drive level RF relative drive level offset in dB
Mtemp
Module
temperature
Module temperature in degrees Celsius
Continued on next page