Specifications

4000326 Rev A Chassis 5-27
Monitor Status Parameters Using the ICIM,
Continued
Monitoring Status Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Power
Supply and Fan Tray Software MODULE menu. From the MODULE menu, press
the
STA T
key to display the STATUS menu.
The following table describes each status parameter.
Parameter Units Values
Ps1Inst N/A
1 if slot 1 power supply is installed
0 if power supply is not installed
Ps1+24V V Slot 1 power supply +24 V output voltage
Ps1+5V V Slot 1 power supply +5 V output voltage
Ps1-5V V Slot 1 power supply -5 V output voltage
Ps1Temp °C Internal temperature of slot 1 power supply
Chas+24V V Voltage on the chassis +24 V rail
Chas+5V V Voltage on the chassis +5 V rail
Chas-5V V Voltage on the chassis -5 V rail
ChasTemp °C Internal temperature of the fan tray
FansOn N/A
1 if fans are running
0 if the fans are shut off