Specifications
4-44 Optical Amplifiers 4000326 Rev A
Configure Parameters Using LCI
Introduction
The LCI software allows you to configure several amplifier parameters.
Configuring Parameters
To configure the parameters, navigate to the Module Details window of the
amplifier (in the LCI module tree). The parameters are shown under the Controls
heading.
The following table shows the configurable parameters for the amplifier.
Parameter Description Values Default
Enable Laser
Turns optical amplifier
on/off.
• On = Enabled
• Off = Disabled
Enabled
Optical
Power
Attenuation
Optical power attenuation.
• 0 dB to 3.0 dB in
1.0 dB steps
0.0 dB
Master
Master (default). When set
to Slave, will only start with
an external alarm signal.
• On = Master
• Off = Slave
Master
Low Input
Alarm
Inhibit
Disables low input alarm.
• On = Alarm Enabled
• Off = Alarm Disabled
Alarm
Enabled