Specifications
4000326 Rev A Optical Amplifiers 4-41
Modify Alarm Limits Using LCI
Introduction
Using LCI, you can modify limits for several alarm parameters for the amplifier.
Modifying Alarm Parameters
To modify the parameters, navigate to the Module Details window of the amplifier
(in the LCI module tree). The parameters are shown under the Parameters heading.
The following table shows parameters with alarm limits that can be modified.
Parameter Meaning
Major Low
Threshold
Minor Low
Threshold
Minor High
Threshold
Major High
Threshold
Hysteresis
Laser Bias
Current
Laser
bias
current
-32 A -32 A -.1 A -.01 A .001 A
Output
Power
Optical
output
-1.0 dBm -0.7 dBm 0.7 dBm 1.0 dBm 0.1 dBm