Specifications
4000326 Rev A Optical Amplifiers 4-35
Monitor Alarm Parameters Using the ICIM,
Continued
Monitoring Alarm Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Optical
Amplifier MODULE menu. From the MODULE menu, press the
ALRM
key to
display the ALARMS menu.
The following table describes each amplifier alarm parameter.
Parameter Meaning
Major Low
Threshold
Minor Low
Threshold
Minor High
Threshold
Major High
Threshold
Hysteresis
LasBias Laser
bias
current
-32 A -32 A -.1 A -.01 A .001 A
InPwr Optical
input
power
-15.0 dBm -5.0 dBm 20.0 dBm 45.0 dBm 1.0 dBm
OutPwr Optical
output
-1.0 dBm -0.7 dBm 0.7 dBm 1.0 dBm 0.1 dBm
Enable Module
on or off
N/A N/A N/A N/A N/A
Laser
Tempera-
ture
Laser
tempera-
ture
-9.0°C -9.0°C 30.0°C 45.0°C 1.0°C
IntPs Power
supply
fault
N/A N/A N/A N/A N/A