Specifications
4000326 Rev A Optical Switches 3-9
Monitor Status Parameters,
Continued
Monitoring Status Parameters
The following table describes each status parameter.
Parameter Meaning Values
Summary
STATUS
Screen:
• PoptA
Received optical power for input A -13.0 dBm to +18.0 dBm
• PoptB
Received optical power for input B -13.0 dBm to +18.0 dBm
• SMC
SMC ID of the switch
Programmable
0001 to 65535
PoptA Received optical power for input A -13.0 dBm to +18.0 dBm
PoptB Received optical power for input B -13.0 dBm to +18.0 dBm
Primry
Primary input
Note: The asterisk indicates non-
revertive mode.
• A
• B
Posit Bar/Cross position
• Bar
• Cross
BackUp Primary/Backup
• Primary
• Backup
Posit Switch position
• Bar
• Cross
Auto/Manual Auto or manual mode
• Auto
• Manual
Thrsld Level switching threshold 1.0 dB to 10.0 dB
Hpwr Return level threshold .5 dB to 5.0 dB
Htime Wait time (time hysteresis) 0 to 12 minutes
D5Vdc +5 V digital power level 0 V DC to +10.81 V DC
Continued on next page