Specifications
4000326 Rev A Receivers 2-67
Configure Parameters Using LCI
Introduction
The LCI software allows you to configure several receiver parameters.
Configuring Parameters
To configure the parameters, navigate to the Module Details window of the Receiver
(in the LCI module tree). The parameters are shown under the Controls heading.
The following table shows the configurable parameters for the receiver.
Parameter Description Values Default
• Rx 1 Mute Switch
• Rx 2 Mute Switch
Force mute. Muting of the RF
signal and removal of power to
the amplifier only if the Enable
control is on for this particular
side.
• On=Mute on
• Off=Mute off
Off
• Rx 1 Receiver Enable
• Rx 1 Receiver Enable
Enables or disables unit
operation, i.e., muting enabled
and no alarm capability.
• On=Enabled
• Off=Disabled
On
• Rx 1 Manual Alarm
• Rx 2 Manual Alarm
Force alarm. Alarm relay is
manually overridden only if the
Enable control is On. This sets a
particular side to alarm as if there
were an internal alarm, i.e.,
Alarm output high, muting On as
per Force Mute, above.
• On=Alarm on
• Off=Alarm off
Off
• Rx 1 Master Select
• Rx 2 Master Select
Configures the module as master
or slave.
• If set to Master, the unit is
controlled only by the Enable
control, above.
• If set to Slave, the unit is
controlled by a combination
of the Enable control and the
external input CNT_IN_1 or
CNT_IN_2.
• On=Master on
• Off=Slave on
On
• Rx 1 Attenuator
• Rx 2 Attenuator
Sets the attenuation level of the
output RF signal.
Decimal number
between 0.0 and
20.0 dB, increments
of 0.5 dB
0.0 dB