Specifications

4000326 Rev A Receivers 2-63
Configure Parameters Using the ICIM
Introduction
The CONFIG menu on the ICIM allows you to configure several receiver parameters.
Configuring Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Reverse
Receiver MODULE menu. From the MODULE menu, press the
CFG
key to display
the CONFIG menu.
The following table shows the configurable parameters for the receiver.
Parameter Description Values Default
Mute1
Mute2
Force mute. Muting of the RF signal and
removal of power to the amplifier only if the
Enable control is on for this particular side.
On=Mute on
Off=Mute off
Off
Enable1
Enable2
Enables or disables unit operation, i.e.,
muting enabled and no alarm capability.
On=Enabled
Off=Disabled
On
Alarm1
Alarm2
Force alarm. Alarm relay is manually
overridden only if the Enable control is On.
This sets a particular side to alarm as if there
were an internal alarm, i.e., Alarm output
high, muting On as per Force Mute, above.
On=Alarm on
Off=Alarm off
Off
Master1
Master2
Configures the module as master or slave.
If set to Master, the unit is controlled only
by the Enable control, above.
If set to Slave, the unit is controlled by a
combination of the Enable control and the
external input CNT_IN_1 or CNT_IN_2.
On=Master on
Off=Slave on
On
Atten1
Atten2
Sets the attenuation level of the output
RF signal.
Decimal number
between 0.0 and
20.0 dB,
increments of
0.5 dB
0.0 dB
NomPwr1
NomPwr2
The nominal input optical power level,
in dBm.
Decimal number
between –20.0
and 0.0 dBm,
increments of 0.5
dBm
0.0 dBm