Specifications

2-62 Receivers 4000326 Rev A
Monitor Status Parameters Using the ICIM
Introduction
The STATUS menu on the ICIM allows you to verify the status of the receiver.
Status Information
The following receiver status information is available.
Optical power level
Module temperature
Mute status
Manual (forced) alarms
Receiver enabled/disabled
Master/Slave mode
Nominal input power level
Monitoring Status Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Reverse
Receiver MODULE menu. From the MODULE menu, press the
STA T
key to display
the STATUS menu.
The following table describes each receiver status parameter.
Parameter Meaning Operating Range
InPwr1 Optical input power for Rx 1 -17.0 dBm to +2.0 dBm
InPwr2 Optical input power for Rx 2 -17.0 dBm to +2.0 dBm
ModTemp Module temperature
-40.0°C and 65.0°C
Mute1 Mute status for Rx 1 On or Off
Mute2 Mute status for Rx 2 On or Off
Alarm 1 Alarm for Rx 1 On or Off
Alarm 2 Alarm for Rx 2 On or Off
Enable 1 Rx 1 enabled On or Off
Enable 2 Rx 2 enabled On or Off
Master 1 Rx 1 master On or Off
Master 2 Rx 2 master On or Off
NomPwr1 Nominal input power -20.0 dBm to 0.0 dBm
NomPwr2 Nominal input power -20.0 dBm to 0.0 dBm