Specifications
4000326 Rev A Receivers 2-61
Monitor Alarm Parameters Using the ICIM,
Continued
Monitoring Alarm Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Reverse
Receiver MODULE menu. From the MODULE menu, press the
ALRM
key to display
the ALARMS menu.
The following table describes each receiver alarm parameter.
Parameter Meaning
Major
Low Limit
Minor
Low Limit
Minor
High
Limit
Major
High
Limit
Hysteresis
Operating
Range
InPwr1
Optical
input 1
-20.0 dBm -4.0 dBm 2.0 dBm 3.2 dBm 1.0 dBm
-17.0 dBm to
+2.0 dBm
InPwr2
Optical
input 2
-20.0 dBm -4.0 dBm 2.0 dBm 3.2 dBm 1.0 dBm
-17.0 dBm to
+2.0 dBm
ModTemp
Module
tempera-
ture
-125.0°C -85.0°C 85.0°C 125.0°C 1.0°C
-40.0°C and
65.0°C
InPwr1Mx
Maximum
optical
input
power
limit
-100.0
dBm
-100.0
dBm
3.2 dBm 3.2 dBm
N/A
N/A
InPwr2Mx
Maximum
optical
input
power
limit
-100.0
dBm
-100.0
dBm
3.2 dBm 3.2 dBm
N/A
N/A
PsOk
Bus
voltage
status
N/A N/A N/A N/A
N/A
N/A
Alarm1
Manual
(forced)
alarm
N/A N/A N/A N/A
N/A
N/A
Alarm2
Manual
(forced)
alarm
N/A N/A N/A N/A
N/A
N/A