Specifications

4000326 Rev A Receivers 2-53
Configure Parameters Using LCI
Introduction
The LCI software allows you to configure several receiver parameters.
Configuring Parameters
To configure the parameters, navigate to the Module Details window of the receiver
(in the LCI module tree). The parameters are shown under the Controls heading.
The following table shows the configurable parameters for the receiver.
Parameter Description Values Default
Enable Enables or disables the receiver
On = Enabled
Off = Disabled
Enabled
Master
When set to Off, receiver begins
operation with an external alarm
signal.
On = Master
Off = Slave
On
Nominal
InPwr
Sets the receiver nominal input
signal level.
5 dBm to -20 dBm 3.0 dBm
Wave
Length
Configures the receiver for 1310 nm
or 1550 nm operation
1310 nm
1550 nm
1550 nm