Specifications
2-48 Receivers 4000326 Rev A
Configure Parameters Using the ICIM
Introduction
The CONFIG menu on the ICIM allows you to configure several receiver parameters.
Configuring Parameters
From the MAIN or SCROLL menus on the ICIM, navigate to the Prisma II Forward
Receiver MODULE menu. From the MODULE menu, press the
CFG
key to display
the CONFIG menu.
The following table shows the configurable parameters for the receiver.
Parameter Description Values Default
Enable Enables or disables the receiver.
• On
• Off
On
Master
Configures the module as
master or slave.
If set to Master Off, the receiver
begins operation with an
external alarm signal
• On
• Off
On
WaveLen
Configures the receiver for 1310
nm or 1550 nm operation.
• 1310 nm
• 1550 nm
1550 nm
NomPin Sets the nominal input level.
+5.0 dBm to –20.0 dBm
in 0.5 dBm steps
3.0 dBm