Specifications
4000326 Rev A Receivers 2-35
Monitor Status Parameters,
Continued
Monitoring Status Parameters
The following table describes each status parameter.
Parameter Meaning Values
Summary
STATUS
Screen:
• POpt1
Received optical power for RX 1 -3.0 dBm to +3.0 dBm
• POpt2
Received optical power for RX 2 -3.0 dBm to +3.0 dBm
• ID
SMC ID of the module 0000 to 65,535
Received optical power status for RX 1. OK, HIGH or LOW
POpt1
Received optical power level for RX 1. -17.0 dBm to 0.0 dBm
Received optical power status for RX 2. OK, HIGH or LOW
POpt2
Received optical power level for RX 2. -17.0 dBm to 0.0 dBm
HIGH
(if receiver is set for high gain)
• Gain1
• Gain2
Receiver gain state for RX 1 and RX 2.
LOW
(if receiver is not set for high
gain)
• ROut1
• ROut2
Relative RF output level for RX 1 and RX 2.
Output level displayed as a
percentage.
• 0% indicates 20.0 dB
attenuation
• 100% indicates no
attenuation
SNGL
Single receiver mode. RX 2 acts
as a hot backup for RX 1.
Path Receiver path status (non-backup mode)
DUAL
Dual receiver mode. RX 1 and
RX 2 function independently of
each other
Continued on next page