Specifications

2-22 Receivers 4000326 Rev A
Monitor Status Parameters,
Continued
Status Parameters
The following table describes each status parameter.
Parameter Meaning Description
POpt Received optical
power
Input optical power ID, status, and power
level.
Ihybd Hybrid current draw Low or high hybrid current indicates a
possible hybrid failure, requiring the
amplifier to be repaired.
Contact Scientific-Atlanta for hybrid repair.
For instructions, refer to Chapter 6,
Customer Information.
LoPwr Low optical input Optical input is out of nominal input range.
HiPwr High optical input Optical input is out of nominal input range.
Mtemp Module temperature Module temperature in degrees Celsius
D5Vdc
+5 V DC digital
power level
+5 V DC supply for digital circuitry status
A5Vdc
+5 V DC analog
power level
+5 V DC supply for analog circuitry status
-5Vdc
-5 V DC backplane
power level
-5 V DC power status
15Vdc
+15 V DC control
card power level
+15 V DC control card status
24Vdc
+24 V DC analog
power level
+24 V DC power status
PSpri Power supply Primary backplane power supply status
PSsec Power supply Secondary backplane power supply status