Specifications

1-116 Transmitters 4000326 Rev A
Monitor Status Parameters Using LCI,
Continued
Monitoring Status Parameters
To monitor the parameters, navigate to the Module Details window of the
Transmitter (in the LCI module tree). The alarms are shown under the Parameters
and Status headings.
The following table describes each transmitter status parameter.
Parameter Units Meaning Typical Value
RF Input dB Relative RF input power 0 dB
Output Power 1 dBm Optical output power at port 1 +9.0 dBm
Output Power 2 dBm Optical output power at port 2 +9.0 dBm
Module
Temperature
°C Module temperature Ambient °C + 15.0°
Laser
Temperature
°C Laser temperature
30.0°C
TEC Current A Measured TEC current 0.2A
Laser Bias mA Measured laser current 270 mA
SBS 2GHz
Power
N/A Lock detect, SBS 2GHz PLL
Lock
SBS 6GHz
Power
N/A Lock detect, SBS 6GHz PLL
Lock
-5V Supply
Voltage
VN/A Internal -5 V power level
-5 V
-12V Supply
Voltage
V Internal -12 V power level -12 V
+12V Supply
Voltage
V Internal +12 V power level +12 V