Installation Guide
44 4030542 Rev B
Using the Main Configuration Screen
This feature requires firmware version B2 or higher. Note:
Use the
to navigate and the arrow keys Space Bar to change the values on this
screen.
The following table describes the settings available on this screen.
Setting Description
Unit FlowControl Enable/Disable FlowControl.
Unit FiberAlert Enable/Disable FiberAlert.
Unit Loopback Enable/Disable the various LoopBack testing modes.
Unit Max FrameSz Set the maximum Frame Size to pass through the ports: 1518, 1522,
1536, or 1916.
802.1p Base Prj Set the level of 802.1p base priority (3 or 4).
The Mini FiberLinX-II has two outgoing queues: one for high
priority traffic and one for low priority traffic. If the Base VLAN
Priority is 4 for example, 0-3 are low priority and 4-7 are high
priority. If the Base VLAN Priority is changed to 3, 0-2 are low
priority and 3-7 are high priority.
Serial Configuration/Telnet Session
To manage access to the Mini FiberLinX-II, type
accounts and then press Enter from
the command screen. The following screen appears:
To add a user, press
A, and then enter the user information in the appropriate
fields.
To delete a user, press
D for the user selected.
To exit this screen, press any key other than A or D.
User rights only allow viewing of status/settings but not changing of settings. Note: