System information
Open and resolved caveats in TC6
65
Open caveats in TC6.1.1
For open caveats regarding other endpoints/vendors, see the interoperability section.
Reference ID
Endpoint /
Device
Versions
affected
Fix
Target
Summary
CSCuh50086
All TC
endpoints
6.1.x
6.2.0
H323 Multiway Accept&Merge fails in 6.1.x
CSCug76672
All TC
endpoints when
using VCS
6.0.x
6.1.x
6.2.0
The encryption padlock does not appear when
encryption is set to ON. It does not help to set the
GUI EncryptionIndicator to “Always On”. The
functionality used to be like this:
If Encryption is set to “On” then always display the
padlock in call.
CSCuh37718
TC endpoints
using remote
control
6.1.x
6.2.0
Enabling Do Not Disturb is implemented in different
ways on OSD and Touch. On Touch it will
automatically be turned off after x minutes defined
by xConfiguration Conference 1 DoNotDisturb
DefaultTimeout. Using the Remote it will be enabled
until turned off.
CSCug37656
All TC
endpoints
6.0.x
6.1.0
6.2.0
Fan status in system information on web might be
misinterpreted. Although it may report “fans not
running” or “can’t match [RPM] rpm” it does not
mean that the system is faulty or that there is a
problem with the fans. If the system is operating
within the temperature specification, customer or
TAC should take no action. The diagnostic
messages and system information statuses will be
improved.
CSCuf93352
SX20
6.0.x
6.2.0
When an SX20 is in standby mode and is reloaded
from the GUI, it comes up correctly, however, the
display connected to HDMI1 does not come out of
standby. The display on HDMI2 comes correctly out
of standby.
CSCue78225
Touch 8
6.0.x
6.2.0
When starting a presentation from the Touch 8”, the
presentation dialog goes to the secondary camera
instead of the PC. PC input has been set as the
default presentation source.
CSCug13558
All TC
endpoints
6.0.x
6.2.0
The remote service supports the use of anonymous
SSL ciphers.
CSCue62562
All TC
endpoints
6.0.x
6.2.x/7.x
When a login is required for the OSD
(xConfiguration Video OSD LoginRequired: on),
only a username and PIN are required to log into
the OSD. Thus, if no PIN is configured, non-admin
users can log into the OSD as admin, giving them
access to admin-level system configuration. No
password is required.
CSCug13548
All TC
endpoints
6.0.x
6.1.x
6.2.0
The remote service supports the use of medium
strength SSL ciphers
CSCue94398
Touch 8
6.0.x
6.1.x
6.2.0
When setting PresentationSelection hidden, the
input is still available in Touch UI.