System information
Open and resolved caveats in TC6
63
Open caveats in TC6.1.2
For open caveats regarding other endpoints/vendors, see the interoperability section.
Reference ID
Endpoint /
Device
Versions
affected
Fix
Target
Summary
CSCtq44757
5.x
6.x
7.0.x
The TC software is configured with the default
SNMP community strings. This is needed for “plug
and play” functionality, but SNMP community
strings should be treated as “credentials” and
therefore this must be changed after initial
configuration.
CSCub01177
VCS registered
TC endpoints
5.x
6.x
7.0.x
We should send the RPID header when registered
to a VCS. Currently this is only done when SIP is
set to CISCO (CUCM) mode.
CSCuc64777
All TC
endpoints
5.1.x
6.x
6.3.x
Confusing call setup for p2p OBTP meetings. For
the second participant joining, the answer button will
change from Join Meeting to Incoming Call. When
button is clicked a new message appear with two
options; “join meeting and end current” or dismiss.
CSCua42948
C60
C90
5.x
6.0.x
6.1.x
6.3.x
When using custom layouts and presenting on C-
series codecs, no layout options are available in the
layout menu when the resolution of the presentation
source is set to certain values. The configured
layouts appear in the menu as expected when the
resolution is not set to those values.
CSCug89221
Touch 8
6.1.1
6.3.x
Touch panel running release TT6.1.1 keeps on
sending DHCPREQUESTS every 10 seconds.
CSCug58614
Touch 8
5.x
6.0.x
6.1.x
6.3.x
Network paired endeavour loses pairing from time to
time and does not automatically reconnect
CSCuh50086
All TC
endpoints
6.1.x
6.2.0
H323 Multiway Accept&Merge fails in 6.1.x
CSCug76672
All TC
endpoints when
using VCS
6.0.x
6.1.x
6.2.0
The encryption padlock does not appear when
encryption is set to ON. It does not help to set the
GUI EncryptionIndicator to “Always On”. The
functionality used to be like this:
If Encryption is set to “On” then always display the
padlock in call.
CSCuh37718
TC endpoints
using remote
control
6.1.x
6.2.0
Enabling Do Not Disturb is implemented in different
ways on OSD and Touch. On Touch it will
automatically be turned off after x minutes defined
by xConfiguration Conference 1 DoNotDisturb
DefaultTimeout. Using the Remote it will be enabled
until turned off.
CSCug37656
All TC
endpoints
6.0.x
6.1.0
6.2.0
Fan status in system information on web might be
misinterpreted. Although it may report “fans not
running” or “can’t match [RPM] rpm” it does not
mean that the system is faulty or that there is a
problem with the fans. If the system is operating
within the temperature specification, customer or
TAC should take no action. The diagnostic
messages and system information statuses will be