System information
Open and resolved caveats in TC6
42
Reference ID Summary
CSCuh32320
Polycom RMX sends encrypted media that fails to decrypt and decode because TC
software is not handling the MKI byte in the SRTP correctly.
CSCui47228
TC6.2.0 fails to send OLC ack to MCU intermittently. This causes no video and audio
received from the MCU.
CSCui49305
Wrong time zone set at endpoint when provision from CUCM - America/Lima.
Platform
Reference ID Summary
CSCuj12197
Connect to codec via serial and make sure login for serial is on. On 1st connection
codec prompts correctly: login:
If you after this enter an invalid password it will INCORRECTLY form the promt with
system name and a blank: <my systemname> login:
This is critical for integration with Crestron. Crestron have customers complain about
systems failing to connect after upgrading to TC 6.1.
Web
Reference ID
Summary
CSCuj28178
Signing in to the web interface using client certificate does not work.
CSCui41456
Presentation statistics are not available in the Web UI for the sender.
Resolved caveats in TC6.2.0
Application
Reference ID Summary
CSCue29288
Dialling numbers with # does not work when using the remote control.
CSCuf74115
Full screen selfview issue in a dual monitor set up: When selfview is in full screen on
monitor two, it will end up as a pip after local presentation has been started and
stopped.
CSCua76593
Users are not able to change the layout via the layout menu on the OSD or the API.
CSCug48377
When setting a monitor to:
* PresentationOnly in all monitor roles