System information

New feature descriptions TC6.2.0
21
Requires TelePresence Touch 8, no support for Remote Control
No TelePresence MCU support
SIP only feature. H323 interworking scenarios are not supported.
Requires that UDP port 5172 is not blocked by any firewall
Active Control is disabled by default. Enabling the features may cause problems with the call
signaling. If an Active Control enabled call traverses a CUCM trunk with a CUCM version lower
than 9.1.2, Active Control fails as the CUCM will zero port the Active Control media lines. ICE and
Active Control cannot be used simultaneously in TC6.2. To enable Active Control, execute
xConfiguration Experimental Conference 1 ActiveControl Mode: On.
New diagnostics warning on web interface
The following diagnostics warnings have been added to the web interface diagnostics troubleshooting
section in TC6.2:
Warning that it will not be possible to make a call when sip listenport is «Off» and SIP outbound is
disabled
Warning when not registered on the protocol (SIP or H323) chosen as the default call protocol
Warning if the SIP profile type is configured incorrectly
Warning if registered to VCS and having TLSVerify On
Notified when having a misconfigured static IP address
Warned whenever the Speed/Duplex setting on the codec is not set to Auto
Warning if the CDP provided Duplex setting of the neighboring switch is different than the reported
duplex setting on the codec
Warning through diagnostics if the system has a missing release key
Reduced support for HTML tags in message alert and message prompts
on screen
For security reasons only <p> and <br> HTML tags are supported in messages on screen (cf.
Message Alert and Message Prompt commands). These tags will result in line breaks as normal. No
other HTML tags will be interpreted; they will appear as text on the screen.
G.729 support for H323 calls
H323 now also supports the G.729 audio codec. G.729 has been supported for SIP from TC6.1.0.