Specifications
Serial Interface Configuration Examples
IC-124
Cisco IOS Interface Configuration Guide
Enable Loopcodes Example
The following interactive example displays two routers connected back-to-back through an FT1/T1
line:
Router# no service-module t1 remote-loopback full
Router# service-module t1 remote-loopback payload alternate
Router# loopback remote full
%SERVICE_MODULE-5-LOOPUPFAILED: Unit 0 - Loopup of remote unit failed
Router# service-module t1 remote-loopback payload v54
Router# loopback remote payload
%SERVICE_MODULE-5-LOOPUPFAILED: Unit 0 - Loopup of remote unit failed
Router# service-module t1 remote-loopback payload alternate
Router# loopback remote payload
%SERVICE_MODULE-5-LOOPUPREMOTE: Unit 0 - Remote unit placed in loopback
Specify Timeslots Example
The following example displays a series of timeslot ranges and a speed of 64 kbps:
Router# service-module t1 timeslots 1-10,15-20,22 speed 64
Display a Performance Report Example
The following is sample output from the show service-module command:
Router1# show service-module s 0
Module type is T1/fractional
Hardware revision is B, Software revision is 1.1i,
Image checksum is 0x21791D6, Protocol revision is 1.1
Receiver has AIS alarm,
Unit is currently in test mode:
line loopback is in progress
Framing is ESF, Line Code is B8ZS, Current clock source is line,
Fraction has 24 timeslots (64 Kbits/sec each), Net bandwidth is 1536 Kbits/sec.
Last user loopback performed:
remote loopback
Failed to loopup remote
Last module self-test (done at startup): Passed
Last clearing of alarm counters 0:05:50
loss of signal : 1, last occurred 0:01:50
loss of frame : 0,
AIS alarm : 1, current duration 0:00:49
Remote alarm : 0,
Module access errors : 0,
Total Data (last 0 15 minute intervals):
1466 Line Code Violations, 0 Path Code Violations
0 Slip Secs, 0 Fr Loss Secs, 0 Line Err Secs, 0 Degraded Mins
0 Errored Secs, 0 Bursty Err Secs, 0 Severely Err Secs, 0 Unavail Secs
Data in current interval (351 seconds elapsed):
1466 Line Code Violations, 0 Path Code Violations
25 Slip Secs, 49 Fr Loss Secs, 40 Line Err Secs, 1 Degraded Mins