Specifications

CSU/DSU Service Module Examples
Configuring Serial Interfaces IC-123
CSU/DSU Service Module Examples
Two main categories of service module examples are provided:
FT1/T1 Examples
2- and 4-wire, 56/64-kpbs Service Module Examples
FT1/T1 Examples
FT1/T1 examples are provided for these configurations:
Specify a T1 Frame Type Example
Specify the CSU Line Build Out Example
Specify T1 Line-Code Type Example
Enable Loopcodes Example
Specify Timeslots Example
Display a Performance Report Example
Enable Loopback Line Examples
Loopback DTE Example
Setting the Clock Source Example
TI CSU WIC Configuration Example
Specify a T1 Frame Type Example
The following example enables super frame as the FT1/T1 frame type:
service-module t1 framing sf
Specify the CSU Line Build Out Example
The following example shows a line build out setting of –7.5 dB:
service-module t1 lbo -7.5db
Specify T1 Line-Code Type Example
The following example specifies AMI as the line-code type:
service-module t1 linecode ami