Specifications
CSU/DSU Service Module Examples
Configuring Serial Interfaces IC-123
CSU/DSU Service Module Examples
Two main categories of service module examples are provided:
• FT1/T1 Examples
• 2- and 4-wire, 56/64-kpbs Service Module Examples
FT1/T1 Examples
FT1/T1 examples are provided for these configurations:
• Specify a T1 Frame Type Example
• Specify the CSU Line Build Out Example
• Specify T1 Line-Code Type Example
• Enable Loopcodes Example
• Specify Timeslots Example
• Display a Performance Report Example
• Enable Loopback Line Examples
• Loopback DTE Example
• Setting the Clock Source Example
• TI CSU WIC Configuration Example
Specify a T1 Frame Type Example
The following example enables super frame as the FT1/T1 frame type:
service-module t1 framing sf
Specify the CSU Line Build Out Example
The following example shows a line build out setting of –7.5 dB:
service-module t1 lbo -7.5db
Specify T1 Line-Code Type Example
The following example specifies AMI as the line-code type:
service-module t1 linecode ami