Specifications
7-6
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 7 TL1 Alarms and Errors
Alarms
7.1.11 EXT-SREF
BITS outgoing references (SYNC-BITS1, SYNC-BITS2)
7.1.12 FAN
Fan-tray assembly
PEER-
NORESPONSE
MA/NSA The switch agent raises a Peer Card Not Responding alarm if
either I/O card in a protection group does not receive a response
to the peer status request message.
SFTWDOWN-FAIL MI/NSA The software download from the TCC+/XTC card to the ONS
15454 failed.
SNTP-HOST MI/NSA An ONS node serving as an IP proxy for the other ONS nodes in
the ring is not forwarding SNTP information to the other ONS
nodes in the network.
SWMTXMOD CR/SA Traffic on the reporting card is lost when this failure occurs.
Table 7-10 EQPT (continued)
EQPT Alarm
Severity
(Active) Description
Ta b l e 7- 11 E X T- S R E F
EXT-SREF Alarm
Severity
(Active) Description
SYNCPRI MI/NSA A loss of the primary timing source (reference 1).
SYNCSEC MI/NSA A loss of the secondary timing source (reference 2).
SYNCTHIRD MI/NSA A loss of the third timing source (reference 3).
Ta b l e 7- 1 2 FA N
FAN Alarm
Severity
(Active) Description
EQPT-MISS CR/SA Indicates the replaceable fan tray assembly unit is missing or not
fully inserted.
FAN CR/SA A problem with the fan-tray assembly.
MEA CR/SA The mismatch between entity/equipment type and provisioned
attributes alarm occurs when the physical card inserted in a slot does
not match the card type that is provisioned for that slot in the CTC.
MFGMEM CR/SA The manufacturing data memory failure alarm means that the
ONS 15454/ONS 15327cannot access the data on the erasable
programmable read-only memory (EPROM).