Specifications
7-5
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 7 TL1 Alarms and Errors
Alarms
7.1.10 EQPT
A card in any of the card slots. This object is used for alarms that refer to the card itself and all other
objects on the card including ports, lines, STS and VT.
Ta b l e 7- 1 0 E Q P T
EQPT Alarm
Severity
(Active) Description
AUTORESET MI/NSA The card is performing a warm reboot automatically.
BKUPMEMP CR/NSA A problem with the TCC+/XTC card’s flash memory.
CARLOSS MI/NSA The Ethernet card has lost its link and is not receiving any signal,
even an invalid one.
CONTBUS-A-18 MA/NSA The main processor on the TCC+/XTC card in Slot 7/Slot 5 has
lost communication with the coprocessor on the second
TCC+/XTC card in Slot 11/Slot 6.
CONTBUS-A MA/NSA The TCC+/XTC card in Slot 7/Slot 5 has lost communication with
a line card.
CONTBUS-B-18 MA/NSA The main processor on the TCC+/XTC card in Slot 11/Slot 6 has
lost communication with the coprocessor on the TCC+/XTC card
in Slot 7/Slot 5.
CONTBUS-B MA/NSA The TCC+/XTC card in Slot 11/Slot 6 has lost communication
with a line card.
CTNEQPT-PBPROT CR/SA A failure of the main payload between the protect cross-connect
(XC/XCVT/XC10G) card in Slot 10, or the protect XTC card, and
the reporting traffic card.
CTNEQPT-PBWORK CR/SA The main payload bus between the active cross-connect
(XC/XCVT/XC10G) card in Slot 8, or the active XTC card, and
the reporting traffic card.
EQPT CR/SA A hardware failure occurred on the reporting card.
EXCCOL MI/NSA There are too many collisions are occurring on the network
management LAN.
HITEMP MI/NSA The temperature of the ONS 15454/ONS 15327 is above 50
degrees Celsius.
IMPROPRMVL CR/SA A card was physically removed from its slot before the card was
deleted in CTC.
MEA CR/SA The mismatch between entity/equipment type and provisioned
attributes alarm occurs when the physical card inserted in a slot
does not match the card type that is provisioned for that slot in the
CTC.
MEM-GONE MA/NSA Data generated by software operations exceeds the memory
capacity of the TCC+/XTC card.
MEM-LOW MI/NSA Data generated by software operations is close to exceeding the
memory capacity of the TCC+XTC card.