Specifications
4-27
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
September 2002
Chapter 4 TL1 Command Components
Parameter Types
FE-DS3-NSA Non-service affecting failure detected from the far-end DS3
FE-DS3-SA Service affecting failure detected from the far-end DS3
FE-EQPT-NSA Non-service affecting equipment failure is detected from the far-end
DS3
FE-EXERCISING-RING Far End Exercise Ring
FE-EXERCISING-SPAN Far End Exercise Span
FE-FRCDWKSWPR-RING Working facility forced to switch to protection unit - Ring Far end
FE-FRCDWKSWPR-SPAN Working facility forced to switch to protection unit - Span Far end
FE-IDLE Far end node detects an idle DS3 signal
FE-LOCKOUTOFPR-ALL Far end LockOut All Protection Channels of the network
FE-LOCKOUTOFPR-RING Far End Lockout Of Protection - Ring
FE-LOCKOUTOFPR-SPAN Far End Lockout Of Protection - Span
FE-LOCKOUTOFWK-RING Far End Lockout Of Working - Ring
FE-LOCKOUTOFWK-SPAN Far End Lockout Of Working - Span
FE-LOF Far end node reports a DS3 loss of frame
FE-LOS Far end node reports a DS3 loss of signal
FE-MANWKSWPR-RING Far end Manual Ring Switching command is activated
FE-MANWKSWPR-SPAN Far end Manual Span Switching command is activated
FE-SD-RING Far end detected SD on Working channel and issued a Ring Switch
FE-SD-SPAN Far end detected SD on Working channel and issued a Span Switch
FE-SDPRLF Far end detected SD on Protection Channel
FE-SF-RING Far end detected SF on Working channel and issued a Ring Switch
FE-SF-SPAN Far end detected SF on Working channel and issued a Span Switch
FEBE External failure - Incoming - Far End Block Error
FEPRLF External failure - Incoming - Automatic Protection Switching
Channel - Far End Protection Line Failure
FORCED-REQ Forced switch request on facility/equipment
FORCED-REQ-RING Forced switch request on a Ring
FORCED-REQ-SPAN Forced switch request on a Span
FRCDWKSWBK Recovery action - Working facility/equipment forced to switch back
to working
FRCDWKSWPR Recovery action - Working facility/equipment forced to switch to
protection unit
FRCDWKSWPR-PATH Recovery action - Working facility/equipment forced to switch to
protection unit - Path
FRCWKBK-R Working facility/equipment forced to switch back to working - Ring
FRCWKBK-S Working facility/equipment forced to switch back to working - Span
Table 4-46 CONDITION Values (continued)
CONDITION Values Description