Specifications

4-2
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 4 TL1 Command Components
TL1 Default Values
4.1.3 Environmental Alarms and Controls
4.1.4 Equipment
4.1.5 Performance
Table 4-3 Environmental Alarms and Controls
Environmental Alarms and
Controls Default
OPR-EXT-CONT CONTTYPE is set as one provisioned in the respective AID, there is not
default for it. It is only used as a filter if entered. DUR is always taken as
CONT.
RTRV-ATTR-CONT There is no default for CONTTYPE. It is only used as a filter if entered.
RTRV-ATTR-ENV There is no default for both NTFCNCDE and ALMTYPE, which are only
used as filters if entered.
RTRV-EXT-CONT CONTTYPE defaults to the conttype associated with the AID.
SET-ATTR-ENV NTFCNCDE defaults to NR. ALMTYPE defaults to NULL. ALMMSG
defaults to \“Env Alarm Input 1\”.
Table 4-4 Equipment
Equipment Default
ALW-SWTOPROTN-EQPT,
INH-SWTOPROTN-EQPT
and ALW-SWTOWKG-EQPT,
ING-SWTOWKG-EQPT
DIRN defaults to BTH.
ENT-EQPT PROTID, PRTYPE, RVRTV and RVTM defaults to NULL.
SW-DX-EQPT MODE defaults to NORM.
SW-TOPROTN-EQPT and
SW-TOWKG-EQPT
MODE defaults to NORM. DIRN defaults to BTH.
Table 4-5 Performance
Performance Default
INIT-REG-<MOD2> LOCN defaults to NEND (near end).
RTRV-PM-<MOD2> LOCN defaults to NEND.
TMPER defaults to 15 minutes.