Chapter 3 TL1 Command Descriptions
TL1 Commands
3.5.127 SW-DX-EQPT: Switch Duplex Equipment
(Cisco ONS 15454 only)
This command switches an XC/XCVT card with the mate card within the NE.
Note If sending a mode parameter with a value other than NORM, FRCD, or NULL, the IDNV (Input, Data
Not Valid) error message will be returned.
Input Format SET-TOD:[<TID>]::<CTAG>::<YEAR>,<MONTH>,<DAY>,<HOUR>,
<MINUTE>,<SECOND>,[<DIFFERENCE>][:DST=<DST>];
where:
<YEAR> is the current calendar year and is an integer
<MONTH> is the month of the year and ranges from 01–12; <MONTH> is an
integer
<DAY> is the day of the month and ranges from 01–31; <DAY> is an integer
<HOUR> is the hour of the day and ranges from 00–24; <HOUR> is an integer
<MINUTE> is the minute of the hour and ranges from 00–60; <MINUTE> is an
integer
<SECOND> is the second of the minute and ranges from 00–59; second is an
integer
<DIFFERENCE> is the number of minutes off UTC and is an integer
<DST> identifies if the time is a Daylight Saving Time (Y) or not (N); valid
values for <DST> are shown in the “ON_OFF” section on page 4-51
Input Example SET-TOD:CAZADERO::240::1998,05,08,13,18,55,480:DST=Y;
Errors This message generates all the default errors
Section SET-TOD Description (continued)
Section SW-DX-EQPT Description
Category Equipment
Security Maintenance
Related
Messages
ALW-SWDX-EQPT INH-SWTOWKG-EQPT
ALW-SWTOPROTN-EQPT REPT ALM EQPT
ALW-SWTOWKG-EQPT REPT EVT EQPT
DLT-EQPT RTRV-ALM-EQPT
ED-EQPT RTRV-COND-EQPT
ENT-EQPT RTRV-EQPT
INH-SWDX-EQPT SW-TOPROTN-EQPT