Specifications
3-117
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 3 TL1 Command Descriptions
TL1 Commands
3.5.83 RTRV-ALM-BITS: Retrieve Alarm Building Integrated Timing Supply
This command instructs the NE to retrieve and send the current status of its alarm conditions associated
with the BITS facility. The alarm condition or severity retrieved is specified using the input parameters
as a filter.
Output Format SID DATE TIME
M CTAG COMPLD
“[<AID>],[<AIDTYPE>]:<NTFCNCDE>,<CONDTYPE>,<SRVEFF>,,,,:
[<DESC>],[<AIDDET>]”
;
where:
• <AID> is the identifier that has an alarm condition and is from the “ALL”
section on page 4-5, <AID> is optional
• <AIDTYPE> is the type of access identifier; valid values for <AIDTYPE> are
shown in the “MOD2B” section on page 4-45, <AIDTYPE> is optional
• <NTFCNCDE> is the notification code; valid values for <NTFCNCDE> are
shown in the “NOTIF_CODE” section on page 4-49
• <CONDTYPE> is the single type of alarm condition being reported on this
particular line; valid values are shown in the “CONDITION” section on
page 4-24
• <SRVEFF> is the effect on service caused by the alarm condition; valid values
for <SRVEFF> are shown in the “SERV_EFF” section on page 4-56
• <DESC> is the condition description; <DESC> is a string and is optional
• <AIDDET> is the supplementary equipment identification; <AIDDET> is a
string and is optional
Output
Example
TID-000 1998-06-20 14:30:00
M 001 COMPLD
“SLOT-2,EQPT:MN,PWRRESTART,NSA,,,,:\“POWER FAILRESTART\”,
DS1-14”
;
Errors This message generates all the default errors
Section RTRV-ALM-ALL Description (continued)
Section RTRV-ALM-BITS Description
Category Synchronization
Security Retrieve