Specifications

3-60
Cisco ONS 15454 and Cisco ONS 15327 TL1 Command Guide, R3.3
May 2002
Chapter 3 TL1 Command Descriptions
TL1 Commands
3.5.30 ED-SYNCN: Edit Synchronization
This command edits the synchronization reference list used to determine the sources for the NE's
reference clock and the BITS output clock. For each clock, up to three synchronization sources may be
specified (e.g., PRIMARY, SECOND, THIRD).To view or edit the system timing mode, use the
RTRV-NE-SYNCN or ED-NE-SYNCN commands.
Note To retrieve/set the timing mode, SSM message Set or Quality of RES information, use the
RTRV-NE-SYNCN and ED-NE-SYNCN commands.
Input Example ED-PID:CISCO:UID:123::OLDPID,NEWPID;
Errors This message generates all the default errors
Section ED-PID Description (continued)
Section ED-SYNCN Description
Category Synchronization
Security Provisioning
Related
Messages
ED-BITS RTRV-ALM-BITS
ED-NE-SYNCN RTRV-ALM-SYNCN
OPR-SYNCNSW RTRV-BITS
REPT ALM BITS RTRV-COND-BITS
REPT ALM SYNCN RTRV-COND-SYNCN
REPT EVT BITS RTRV-NE-SYNCN
REPT EVT SYNCN RTRV-SYNCN
RLS-SYNCNSW
Input Format
ED-SYNCN:[<TID>]:<AID>:<CTAG>:::[PRI=<PRI>,][SEC=<SEC>,]
[THIRD=<THIRD>][:];
where:
<AID> is the synchronization reference to be modified and is from the
“SYNC_REF” section on page 4-15
<PRI> is the primary reference of the synchronization and is the AID from the
“SYN_SRC” section on page 4-14
<SEC> is the secondary reference of the synchronization and is the AID from the
“SYN_SRC” section on page 4-14
<THIRD> is the third reference of the synchronization and is the AID from the
“SYN_SRC” section on page 4-14
Input Example ED-SYNCN:BOYES:SYNC-NE:112:::PRI=INTERNAL,SEC=INTERNAL,
THIRD=INTERNAL;
Errors This message generates all the default errors