3.5.20 ED-BLSR: Edit Bidirectional Line Switched Ring
This command edits the BLSR attributes.
Notes:
1. Only the RVRTV, RVTM, SRVRTV, SRVTM attributes can be edited for the 4-Fiber BLSR.
2. Only the RVRTV and RVTM attributes can be edited for the 2-Fiber BLSR.
Error conditions:
1. If there is a system error, an SDBE (Status, Internal Data Base Error) error message will be returned.
2. If the NE returns nothing for the required BLSR (BLSR number, AID), a SRQN (Status, Invalid
Request) error message will be returned.
3. If sending this command to modify any attribute other than RVRTV, RVTM, SRVRTV, and SRVTM
on the 4-Fiber BLSR, an IDNV (Input, Data Not Valid) error message will be returned.
4. If sending this command to modify any attribute other than RVRTV and RVTM on the 2-Fiber
BLSR, an IDNV (Input, Data Not Valid) error message will be returned.
5. If sending this command to modify RVTM while RVRTV is in non-revertive mode or SRVTM while
SRVRTV is in non-revertive mode, an ICNV (Input, Command Not Valid) error message will be
returned.
Section ED-BLSR Description
Category BLSR
Security Provisioning
Related
Messages
REPT ALM RING
REPT EVT RING
RTRV-ALM-RING
RTRV-BLSR
RTRV-COND-RING