Specifications

3-8
Cisco AS5x00 Case Study for Basic IP Modem Services
11/24/1999
Section 3 Commissioning the Cisco AS5800 Hardware
Verifying Basic Setup
--- System Configuration Dialog ---
Would you like to enter the initial configuration dialog? [yes/no]: no
3.
Because the NAS has never been configured, the Cisco IOS cannot find a startup-config file. Abort
the configuration dialog. In this case study, the Cisco IOS is configured manually. The automatic
setup script is not used. Manually configuring the Cisco IOS develops your expertise.
00:00:52: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 12 Succeeded
00:00:53: %DSC_REDUNDANCY-3-BICLINK: Switching to DSC 12
00:00:56: %DSC_REDUNDANCY-3-BICLINK: Link to active DSC up
00:02:05: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 0 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 2 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 3 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 4 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 5 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 6 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 7 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 8 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 9 Succeeded
00:02:06: %DSIPPF-5-DS_HELLO: DSIP Hello from shelf 1 slot 10 Succeeded
Press RETURN to get started!
Router>
4.
By using the DSIP protocol, the router shelf detects the state of each card in the dial shelf.
Depending on how many cards are in the dial shelf, there is a delay of 60 to 120 seconds before the
“DSIP Hello” messages are displayed on your terminal session.
After the Cisco AS5800 is powered up, enter the
show environment
command. Verify that there are
no critical grounding, heating, or power problems. The following example shows a normal operating
environment.
5800-NAS>show environment
All measured values are normal
5800-NAS>show environment all
Power Supplies:
Power supply 1 is empty.
Power supply 2 is Zytek AC Power Supply. Unit is on.
Temperature readings:
chassis inlet measured at 25C/77F
chassis outlet 1 measured at 27C/80F
chassis outlet 2 measured at 33C/91F
chassis outlet 3 measured at 41C/105F
Voltage readings:
+3.45 V measured at +3.49 V
+5.15 V measured at +5.21 V
+12.15 measured at +12.34 V
-11.95 measured at -11.81 V
Envm stats saved 1 time(s) since reload
5800-NAS>