User`s manual
User’s Manual of ISW-1022M Series and ISW-1033MT
[Group Name ]
security-level
[NoAuthNoPriv|AuthNoPriv|Auth
Priv]
match-rule
[Exact|Prifix]
views
[Read View Name] [Write View
Name] [Notify View Name]
iv match-rule Exact views V1 V1 V1
no snmpv3 mibview view
[View Name]
type
[Excluded|Included]
sub-oid
[OID]
G
Remove specified mibview
table of SNMPV3 agent.
switch(config)#no snmpv3 mibview view V1
type Excluded sub-oid 1.3.6.1
6.10 Port Mirroring Commands Set
Commands Level Description Example
monitor
[RX|TX|Both]
I
Configure source port of
monitor function
switch(config)#interface fastEthernet 2
switch(config-if)#monitor RX
monitor rx [Port ID] G
Set RX destination port of
monitor function
switch(config)#monitor rx 2
monitor tx [Port ID] G
Set TX destination port of
monitor function
switch(config)#monitor tx 3
show monitor P
Show port monitor information
switch#show monitor
show monitor I
Show port monitor information
switch(config)#interface fastEthernet 2
switch(config-if)#show monitor
no monitor I
Disable source port of monitor
function
switch(config)#interface fastEthernet 2
switch(config-if)#no monitor
148