Specifications
46 Memory Replacement Instructions for the Network Processing Engine and Input/Output Controller
Removing and Replacing Memory DRAM SIMMs, SDRAM DIMMs, and Boot ROMs
Figure 37 Connecting AC-Input Power to a Cisco 7200 Series Router
Figure 38 Connecting AC-Input Power to a Cisco uBR7200 Series
Step 4
Plug the AC power supply cable into the AC power source.
Note For a Cisco 7200 series router, each AC-input power supply operating at 120 VAC requires a
minimum of 5A service.
For a Cisco uBR7200 series router, each AC-input power supply operating at 120 VAC requires a
minimum of 7A service.
We recommend powering the Cisco 7200 series routers and the Cisco uBR7200 series routers from
a 120 VAC, 15A receptacle U. S. (240 VAC, 10A international) at the power source.
Step 5 Repeat Step 1 through Step 4 if a second power supply is installed.
This completes the steps for reconnecting AC-input power to a Cisco 7200 series router or
Cisco uBR7200 series router. Proceed to the “Powering Up the Router” section on page 50.
H6848
AC power cable
Cable-retention
clip
Hole for nylon
cable tie
Power switch
H11322
Cable-retention clip
Power switch
Handle
AC power cable
Power receptacle