Specifications
30 Network Processing Engine Replacement Instructions
Removing and Replacing the Network Processing Engine
Figure 19 Connecting AC-Input Power to a Cisco 7200 Series Router
Figure 20 Connecting AC-Input Power to a Cisco uBR7200 Series
Step 4 Plug the AC power supply cable into the AC power source.
Note For the Cisco 7200 series routers, each AC-input power supply operating at
120 VAC requires a minimum of 5A service.
For the Cisco uBR7200 series routers, each AC-input power supply operating at 120 VAC
requires a minimum of 7A service.
We recommend powering the Cisco 7200 series routers and Cisco uBR7200 series
routers from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power
source.
Step 5 Repeat Step 1 through Step 4 if a second power supply is installed.
This completes the steps for reconnecting AC-input power to a Cisco 7200 series router or
Cisco uBR7200 series router. Proceed to the “Powering Up the Router” section on page 34.
H6848
AC power cable
Cable-retention
clip
Hole for nylon
cable tie
Power switch
H11322
Cable-retention clip
Power switch
Handle
AC power cable
Power receptacle
Captive installation screw