(Onboard Administrator modules). The BladeSystem c-Class uses redundant and hot-pluggable 
components extensively to  provide maximum uptime to the enclosure. Figure  1 shows the 
c7000 implementation of the architecture. 
The  HP  BladeSystem  architecture  is  available  in  two  enclosure  form  factors:  the  c7000  and 
the c3000. The HP BladeSystem c7000 enclosure will accommodate up to 16 half-height server 
or other device blades,  or up to eight  full-height  server blades, or  a  combination of the two 
blade form factors. The c7000 also provides eight rear bays for interconnect modules. The HP 
BladeSystem c3000 enclosure will accommodate up to 8 half-height server or other device 
blades, or up to 4 full- height server blades, or a combination of the two blade form factors. The 
c3000 also provides four rear bays for interconnect modules. 
Optional  mezzanine  cards  within  the  server  blades  provide  network  connectivity  to  the 
interconnect modules.  The  connections  between  server  blades  and  the  network  fabric  can  be 
fully redundant. Customers  install  their  choice  of  mezzanine  cards  in  the  mezzanine  slots 
inside  the  blades,  and interconnect modules in the interconnect bays at the rear of the enclosure 
to  create  their  network fabric  connectivity.  Mezzanine  card options include  Ethernet,  Fibre 
Channel,  and  Infiniband. However, Fibre Channel and Infiniband are outside the scope of this 
paper. 
The  enclosure  houses  either  one  or  two  Onboard  Administrator  modules.  Onboard 
Administrator  provides  enclosure-base  management  and  intelligence  throughout  the 
infrastructure  to  monitor  power  and  thermal  conditions,  ensure  hardware configurations  are 
correct,  and  simplify  network configuration.  The  Insight  Display  panel  on  the  front  of  the 
enclosure simplifies configuration and maintenance. Customers have the option of installing a 
second Onboard Administrator module that acts as a completely redundant controller in an active-
standby mode. 
The c7000 enclosure can use either single-phase or three-phase power inputs and can hold up to 
six  2250  W  power supplies. The  power  supplies  connect  to a  passive  power  backplane  that 
distributes the power to all the components in a shared manner. 
To cool the enclosure, HP designed a fan known as the Active Cool fan. The c7000 enclosure 
can hold up to ten hot-pluggable Active Cool fans. The Active Cool fans are designed for high 
efficiency  and  performance  to  provide  redundant  cooling  across  the  enclosure  as  well  as 
providing ample capacity for future cooling needs. 
Figure 1. Overview of c7000 Enclosure Components 