User guide
HP Virtual Connect for Cisco Network Administrators (version 4.x) 
Document Number: C01386629 Date: January 2014 
page 33 
  description FCoE uplink to FlexFabric 
  channel-group 200 mode active 
  lacp rate fast 
  interface Ethernet1/6 
  description FCoE uplink to FlexFabric 
  channel-group 200 mode active 
  lacp rate fast 
Create the VLANs for the IP traffic:  
  vlan 1,10,20 
  Create a trunk on the port channel interface to pass the FCoE (VLAN 200) and Ethernet traffic (VLAN 1,10,20):  
  interface port-channel 200 
  switchport mode trunk 
  switchport trunk allowed vlan 1,10,20,200 
  spanning-tree port type edge trunk 
Create a virtual Fibre Channel interface to carry the FCoE traffic through the port channel:  
  interface vfc 2005 
  bind interface port-channel 200 
  no shutdown 
Assign the vfc interface and the Fibre Channel port to the FCoE VSAN: 
  vsan database 
  vsan 200 
  vsan 200 interface fc2/1 
  vsan 200 interface vfc 2005 
Configure the interface connected to the datacenter LAN:  
  interface eth 1/17 
  switchport mode trunk 
  switchport trunk allowed vlan 1,10,20 
Configuration of the zone: 
Create zones: 
  zone name fcoe-zone vsan 200 
  member pwwn 21:53:00:02:ac:00:15:9d {This is the WWN of the first 3PAR controller port} 
  member pwwn 50:06:0b:00:00:c3:1a:20 {This is the WWN of the Blade FlexFabric Adapter port 