Installation guide
5-18
Cisco Network Convergence System 6000 Series Routers Hardware Installation Guide
Chapter 5 Installing Route Processor Cards, Line Cards, and Fabric Cards
Installing Fabric Cards
Installing an S13 MC Fabric Card
This section describes how to install an S13 Multi-Chassis (MC) fabric card in a Cisco NCS 6000 LCC
for multi-chassis configurations.
Prerequisites
• Shut down the fabric plane (S13 slot number) if configured, to avoid traffic loss. The following
example shows how to shut down plane X (where X is in the range of 0 to 5).
config
controller fabric plane X
shutdown
commit
• Open the cosmetic doors, if installed.
Required Tools and Equipment
• ESD-preventive wrist strap
• Number-2 Phillips screwdriver or Number-2 common (flat-head) screwdriver
• S13 Multi-Chassis Fabric Card
Steps
To install an S13 MC FC card (Figure 5-5) in the NCS 6008 LCC, follow these steps:
Step 1 Attach the ESD-preventive wrist strap to your wrist and connect its leash to one of the two ESD jacks
on the rear side of the LCC (Figure 2-2). You can also connect the ESD-preventive wrist strap leash to
any bare metal surface on the FCC.
Step 2 Remove the card from its antistatic packaging.
Step 3 Determine the FC slot where the card will be installed. For a description of the slot locations, see
Figure 2-3.
Step 4 Orient the card according to the up arrow on the faceplate.
Note If the card does not slide easily into the slot during installation, the orientation may be wrong or the slot
is not for a S13 MC FC.