Datasheet

© 2012-2014 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 4 of 8
A purpose-built optional front-module door provides protection from accidental interference with both the
cabling and modules installed in the system. The transparent front door allows easy observation of cabling
and module indicators and status lights without any need to open the doors, reducing the likelihood of faults
caused by human interference. The door supports a dual-opening capability for flexible operation and cable
installation while fitted. The door can easily be completely removed for both initial cabling and day-to-day
management of the system.
Energy-Efficient Design
The Cisco Nexus 7000 Series uses power supplies that are up to 90 percent efficient, so less power is wasted as
heat, and more power is available for the system to use than with typical power supplies.
The fan modules in the chassis adjust to compensate for changing thermal characteristics. At lower speeds, they
use less power. In the 9-slot chassis, the fan tray is designed to completely turn off the power for a row of fans
when the corresponding slots are unused.
Consolidation of multiple switches in the Cisco Nexus 7000 Series is enabled by the powerful combination of high
density and performance, support for device virtualization, and comprehensive reliability and availability features.
This consolidation increases the power efficiency by reducing wasted power from multiple partially loaded and
inflexible systems.
Product Specifications
Table 1 lists the product specifications for the Cisco Nexus 7000 Series chassis.
Table 1. Product Specifications
Item
Specification
Cisco Nexus 7000 4-Slot
Switch
Cisco Nexus 7000 9-Slot
Switch
Cisco Nexus 7000 10-Slot
Switch
Cisco Nexus 7000 18-Slot
Switch
Product
compatibility
Supports the following Cisco
Nexus 7000 Series
Supervisor and I/O modules:
N7K-SUP2, N7K-SUP2E,
M224XP-23L, M206FQ-23L,
M202CF-22L, M132XP-12L,
M148GS-11L, M148GT-11L,
M108X2-12L, F248XP-25,
F248XT-25
Does not use fabric modules
Supports all Cisco Nexus
7000 Series supervisor and
I/O modules
Supports Fabric2 modules
Supports all Cisco Nexus
7000 Series modules
Supports Fabric1 and
Fabric2 modules
Supports all Cisco Nexus
7000 Series modules
Supports Fabric1 and
Fabric2 modules
Software
compatibility
Cisco NX-OS Software
Release 6.1. (2) Or later
Cisco NX-OS Software
Release 5.2 or later
Cisco NX-OS Software
Release 4.0 or later
Cisco NX-OS Software
Release 4.1 or later
Options
Lockable front module door
Lockable front module door
Air filter
Lockable front module
doors
Lockable front module door
Performance
1.44 billion packets per
second (bpps) (IPv4 Unicast)
in combination with
supervisor module and built-
in fabric
5.04 bpps (IPv4 unicast) in
combination with supervisor
and fabric modules
5.76 bpps (IPv4 unicast) in
combination with supervisor
and fabric modules
11.5 bpps (IPv4 unicast) in
combination with supervisor
and fabric modules
Reliability and
availability
Online insertion and removal
(OIR) of all redundant
components: supervisor
modules, power supplies,
and fan trays
OIR of all redundant
components: supervisor and
fabric modules, power
supplies, and fan trays
OIR of all redundant
components: Supervisor and
fabric modules, power
supplies, and fan trays
OIR of all redundant
components: supervisor and
fabric modules, power
supplies, and fan trays
MIBs
Supports Simple Network
Management Protocol
(SNMP) Versions 3, 2c, and
1 (see Cisco NX-OS
Supports SNMPv3, v2c, and
v1 (see Cisco NX-OS
Software release notes for
details about specific MIB
Supports SNMPv3, v2c, and
v1 (see Cisco NX-OS
Software release notes for
details about specific MIB
Supports SNMPv3, v2c, and
v1 (see Cisco NX-OS
Software release notes for
details about specific MIB