Specifications

15-50
Cisco MWR 2941 Mobile Wireless Edge Router Release 3.5 Software Configuration Guide, Cisco IOS Release 15.1(3)MR
OL-26895-01
Chapter 15 Configuring Ethernet OAM, CFM, and E-LMI
Understanding Microwave 1+1 Hot Standby Protocol
Understanding Microwave 1+1 Hot Standby Protocol
The following sections describe the Microwave 1+1 Hot Standby Protocol (HSBY) protocol:
Overview, page 15-50
HSBY Maintenance Associations, page 15-51
Overview
Microwave 1+1 Hot Standby Protocol (HSBY) is a link protection protocol developed by Nokia Siemens
Networks. HSBY extends the functionality of CFM Continuity Check messages to enable detection and
handling of hardware failures in microwave devices in order to provide redundancy. HSBY provides link
protection support for indoor units (IDUs) and outdoor units (ODUs).
Step 3
ethernet oam [max-rate oampdus | min-rate
seconds | mode {active | passive} | timeout seconds]
Enable Ethernet OAM on the interface
(Optional) Enter max-rate oampdus to set the
maximum rate (per second) to send OAM PDUs. The
range is 1 to 10 PDUs per second; the default is 10.
(Optional) Enter min-rate seconds to set the minimum
rate in seconds.The range is 1 to 10 seconds.
(Optional) Set the OAM client mode as active or
passive. The default is active.
(Optional) Enter timeout seconds to set the time after
which a device declares the OAM peer to be
nonoperational and resets its state machine. The range
is 2 to 30 seconds; the default is 5 seconds.
Step 4
end Return to privileged EXEC mode.
Step 5
copy running-config startup-config (Optional) Save your entries in the configuration file.
Step 6
show ethernet cfm maintenance points remote (Optional) Display the port states as reported by Ethernet
OAM.
Command Purpose