Specifications

B-122
Cisco MWR 2941 Mobile Wireless Edge Router Software Configuration Guide, Release 12.2(33)MRB
OL-21227-02
Appendix B Cisco MWR 2941 Router Command Reference
ethernet oam link-monitor frame-period
Examples The following example shows how to configure an Ethernet OAM link-monitor frame-period window
of 20000 frames:
Router(config-template)# ethernet oam link-monitor frame-period window 2
The following example shows how to configure an Ethernet OAM link-monitor frame-period low
threshold of 500 frames:
Router(config-template)# ethernet oam link-monitor frame-period threshold low 500
Related Commands ethernet oam link-monitor
frame
Configures an error frame threshold or window on an Ethernet OAM
interface.
ethernet oam link-monitor
frame-seconds
Configures a frame-seconds period on an Ethernet OAM interface.
ethernet oam link-monitor
high-threshold action
Configures a specific action to occur when a high threshold for an
error is exceeded on an Ethernet OAM interface.
ethernet oam link-monitor
receive-crc
Configures an Ethernet OAM interface to monitor frames received
with CRC errors for a period of time.
ethernet oam link-monitor
symbol-period
Configures an error symbol period on an Ethernet OAM interface.
ethernet oam link-monitor
transmit-crc
Configures an Ethernet OAM interface to monitor frames transmitted
with CRC errors for a period of time.