Specifications

F-21
Cisco MGX 8800/8900 Series Software Configuration Guide
Release 5.1, Part Number OL-6482-01, Rev. A0, January 25, 2005
Appendix F MPSM Licensing
MPSM Licensing Information
Service Module Serial Number: SAG07208RRA
Provisioning (addcon) Allowed: YES
=========================================================
Needed License Type Needed Licenses
------------------- ---------------
RateControl 1
=========================================================
Allocated License Type Allocated licenses
---------------------- ------------------
RateControl 1
=========================================================
Programmed License Type Programmed licenses
------------------------ -------------------
RateControl 1
=========================================================
Programmed License Registered: YES
License registration node: M8850_SF
Type <CR> to continue, Q<CR> to stop:
License registration chassis: SCA062300GF
=========================================================
M8850_SF.1.28.MPSM8T1.FRM.a >
Note If the switch is in node license alarm, you must rekey the PXM license pool before proceeding with any
other license management tasks. (See “Rekeying Feature Licenses” section on page F-21.)
When the switch is in slot license alarm, you have a grace period of 5 days (120 hours) to resolve the
alarm(s). During the first 4 days (96 hours), traps are sent every 24 hours. For the final 24 hours of the
grace period, traps are sent every hour of operation. If the alarms do not get cleared, the following actions
are taken:
An event is logged indicating the expiration of the grace period for a given slot needing license(s).
A trap is sent hourly indicating the expiration of the grace period.
The addcon command is blocked on the slot in license alarm until the license alarms are cleared.
When the PXM license pool has been rekeyed or licenses have been added to the PXM license pool,
provisioning is restored and the switch exits the license alarm state.
Rekeying Feature Licenses
Use this procedure to get your node out of the Node License Alarm state.
A rekey license can be obtained by contacting Cisco TAC. The rekey license is delivered in the form of
an encrypted key, which appears within an E-mail message or within a text file attached to an E-mail. To
get a rekey license, provide TAC with the output generated by the dsplicnodeid command for the switch
that needs to be rekeyed. The general procedure is as follows:
1. Collect the output generated by the dsplicnodeid command for the destination switch.
2. Contact Cisco TAC, provide the output generated by the dsplicnodeid command from the previous
step, and obtain a rekey license.
3. Apply the rekey license to the destination switch.