Specifications

E-10
Cisco MGX 8800/8900 Series Software Configuration Guide
Release 5.1, Part Number OL-6482-01, Rev. A0, January 25, 2005
Appendix E Hardware Survey and Software Configuration Worksheets
Additional PXM1E Information Configuration Worksheet
Line 11 Redundancy Options
1
Intracard APS Working index
2
slot.2.11
Protection index
2
slot.2.12
Mode
3
Intercard APS Working index
4
slot.2.11
Protection index
5
slot.2.11
Mode
6
Line 12 Redundancy Options
1
Intracard APS Configured while
configuring line 11
Intercard APS Working index
4
slot.2.12
Protection index
5
slot.2.12
Mode
6
1. APS can only be configured on optical lines. For PXM1E-4-155, APS can be configured on lines 1 through 4, and on
PXM1E-8-155, APS can be configured on lines 1 through 8. On PXM1E-COMBO, APS can be configured on lines 9 through
12.
2. Enter the slot number for the standalone PXM1E, which is 1 or 2 on Cisco MGX 8830 and 7 or 8 on MGX 8850 (PXM1E).
3. Valid options: 1+1, 1:1, annexB 1+1, or straight cable 1+1
4. Enter the slot number of the primary PXM1E, which is 1 on Cisco MGX 8830 and 7 on MGX 8850 (PXM1E).
5. Enter the slot number of the secondary PXM1E, which is 2 on Cisco MGX 8830 and 8 on MGX 8850 (PXM1E).
6. Valid options: 1+1, annexB 1+1, or straight cable 1+1
Table E-5 Additional PXM1E Card Configuration Parameters (continued)
Feature
Parameter
Information Value to Configure