| ATMF_VBRrt3(259)| 250000 | 100 | 100 |
|ATMF_VBRnrt1(260)| 250000 | 100 | 100 |
|ATMF_VBRnrt2(261)| 250000 | 100 | 100 |
|ATMF_VBRnrt3(262)| 250000 | 100 | 100 |
| ATMF_UBR1(263)| 250000 | 100 | 100 |
| ATMF_UBR2(264)| 250000 | 100 | 100 |
| ATMF_ABR(265)| 250000 | 0 | 100 |
| ATMF_CBR2(266)| 250000 | 100 | 100 |
| ATMF_CBR3(267)| 250000 | 100 | 100 |
| TAG_COS0(512)| 250000 | 100 | 100 |
| TAG_COS1(513)| 250000 | 100 | 100 |
| TAG_COS2(514)| 250000 | 100 | 100 |
| TAG_COS3(515)| 250000 | 100 | 100 |
| TAG_COS4(516)| 250000 | 100 | 100 |
| TAG_COS5(517)| 250000 | 100 | 100 |
| TAG_COS6(518)| 250000 | 100 | 100 |
| TAG_COS7(519)| 250000 | 100 | 100 |
+-----------------------------------------------+
Table 7-8 describes the SCT ABR Parameters shown in the example.
Table 7-8 SCT Bandwidth Parameter Descriptions
Parameter Description
SERV-TYPE The service type (for example, CBR, VBR, ABR) to which the parameters in this
table apply (for example, COSB_NUM, CAC_TYPE, UPC_ENB).
PCR Specifies the maximum PCR for a connection using this service type. The value is
a percentage of the maximum cell rate for the logical interface. 1000000 is equal
to 100%.
The range and units are 0 to 1000000.
SCR Specifies the SCR
1
for a connection using this service type. The value is a
percentage of the maximum cell rate for the logical interface. 1000000 is equal to
100%.
The range and units are from 0 to 1000000.
1. SCR = sustained cell rate
MCR Specifies the MCR
2
for a connection using this service type. The value is a
percentage of the maximum cell rate for the logical interface. 1000000 is equal to
100%.
The range and units are from 0 to 1000000.
2. MCR = minimum cell rate
MBS Specifies the maximum number of cells that can arrive at a rate equal to the PCR.
The MBS
3
is used for policing.
The range and units are from 1 to 5000000.
CDVT Specifies the CDVT
4
for the first leaky bucket.
ICR Specifies the ICR
5
for a transmission on a connection that has been idle for a
configured period of time. The value is a percentage of the PCR for the logical
interface. 1000000 is equal to 100%.
Note ABR service type connections are used only.
The range and units are from 0 to 1000000.
MFS Specifies the AAL5 MFS
6
in cells.