Specifications
4-4
Cisco MGX 8800/8900 Series Software Configuration Guide
Release 5.1, Part Number OL-6482-01, Rev. A0, January 25, 2005
Chapter 4 Preparing Service Modules for Communication
Managing Firmware Version Levels for Service Modules
Note If any service module displays the Active/Active card state, you do not have to set the runtime
firmware version for that card.
Initializing Service Modules
Before a service module can operate, it must be initialized in a switch slot. The initialization process
defines the runtime software version that will run on the card and identifies the slot in which the card
operates. To initialize a service module, use the following procedure.
Note The line count for all cards in the switch must not exceed the maximum number of lines supported by
the current PXM. The PXM45/A supports 192 UNI/NNI lines. The PXM45/B and PXM45/C support up
to 4,000 UNI/NNI interfaces. Keep this information in mind as you add service modules to your switch.
Step 1 If you have not already done so, determine the software version number for the card by referring to the
following release note documents:
• Release Notes for Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, and Cisco MGX 8830
Switches, Release 5.1.00
• Release Notes for the Cisco MGX 8880 Media Gateway, Release 5.0.02
Tip If you have trouble locating the runtime firmware version level, use the filenames on the PXM
hard disk to determine the level. For more information, see the “Determining the Software
Version Number from Filenames” section in Chapter 9, “Switch Operating Procedures.”
Step 2 Establish a configuration session using a user name with SERVICE_GP privileges or higher.
Step 3 To set the firmware revision level for a card, enter the setrev command in the following format:
mgx8850a.7.PXM.a > setrev <slot> <primary revision> [-ccp <CallControlProtocol>] [-service
<ServiceType>]
Note Each card should be initialized only once with the setrev command. The only other time you
should enter the setrev command is to initialize cards after the card firmware revision level or
service type configuration has been cleared with the clrallcnf <slot#> all command..
Replace <slot> with the card slot number and replace <primary revision> with the software version
number. In addition, use these options if they apply:
• For VXSM cards, add a call control protocol with the ‘-ccp’ option (1: H.248 (default), 2: TGCP, or
3: MGCP)
• For MPSM-16-T1E1 cards, specify a <ServiceType> with the ‘-service’ option (0: ATM/FR
(Default) or 1: MLPPP)
For example,
mgx8850a.7.PXM.a > setrev 1 2.1(60)