Specifications
A-11
Cisco MGX 8850 (PXM45) and MGX 8950 Software Configuration Guide
Release 3, Part Number 78-14788-01 Rev. C0, January 2004
Appendix A Downloading and Installing Software Upgrades
Quickstart Procedures for Software Upgrades
Step 3
cc <primarySlot> Select the slot in which the primary RPM-PR card is installed.
Step 4
enable
password
Enter Enable mode for the router.
Step 5
dir e: Verify router access to the PXM45 hard disk and the boot upgrade
software.
Step 6
show flash: Display current contents of bootflash.
Step 7
copy filename bootflash:
dir bootflash:
Copy the upgrade boot software to flash. For example:
copy e:rpm-boot-mz_002.001.060.000 bootflash:
Step 8
config terminal
boot bootldr bootflash:filename
^Z
show bootvar
Configure the BOOTLDR variable to specify the new boot
software.
Step 9
copy bootflash:filename
c:filename
del bootflash:filename
show flash:
squeeze flash:
Reorganize files in bootflash. The switch always attempts to load
the first bootable file in bootflash. If the BOOTLDR variable is
not set, the new boot software must be the first file listed in the
show flash: display. Copy files you want to save to the c:
directory and delete all files that appear before the new boot
software. Files are marked with the del command and actually
deleted with the squeeze flash: command.
Caution Verify that at least one valid boot or runtime image will
not be deleted. If all boot and runtime images are
deleted from bootflash, the RPM-PR card must be
returned to the factory for repair.
Step 10
switchredcd <primarySlot>
<secondarySlot>
This step makes the secondary card active and resets the primary
RPM-PR card. When the primary card resets, it loads the
upgraded boot software from bootflash.
Step 11
cc <secondarySlot> Select the slot in which the secondary RPM-PR card is installed.
Command Purpose