Specifications

9-10
Cisco MGX 8850 (PXM45) and MGX 8950 Software Configuration Guide
Release 3, Part Number 78-14788-01 Rev. C0, January 2004
Chapter 9 Viewing and Responding to Alarms
Displaying Alarm Reports in the CLI
Displaying Environment Alarms
An environmental alarm report displays the alarm status and operating statistics for the switch power
supplies and cooling fans. To display the environmental alarm report, enter the dspenvalms command
as shown in the following example:
pop20two.7.PXM.a > dspenvalms
pop20two System Rev: 02.00 Sep. 02, 2000 23:40:57 GMT
MGX8850 Shelf Alarm: NONE
ENVIRONMENTAL ALARM STATE INFO ^Notification Disabled
Alarm Type Unit Threshold DataType Value State
---------------- ---- -------------- -------- ---------- -------------
Temperature <= 50 Celsius 29 Normal
Power Supply A1 none None none Missing
Power Supply A2 none None none Missing
Power Supply A3 none None none Missing
DC Voltage A 42 to 54 VoltsDC 0 Normal
Power Supply B1 none None none Missing
Power Supply B2 none None none Missing
Power Supply B3 none None none Missing
DC Voltage B 42 to 54 VoltsDC 0 Normal
Top Fan Tray 1 >= 2000 RPM 3642 Normal
Top Fan Tray 2 >= 2000 RPM 3618 Normal
Top Fan Tray 3 >= 2000 RPM 3714 Normal
Top Fan Tray 4 >= 2000 RPM 3642 Normal
Top Fan Tray 5 >= 2000 RPM 3474 Normal
Type <CR> to continue, Q<CR> to stop:
pop20two System Rev: 02.00 Sep. 02, 2000 23:40:57 GMT
MGX8850 Shelf Alarm: NONE
ENVIRONMENTAL ALARM STATE INFO ^Notification Disabled
Alarm Type Unit Threshold DataType Value State
---------------- ---- -------------- -------- ---------- -------------
Top Fan Tray 6 >= 2000 RPM 3654 Normal
Top Fan Tray 7 >= 2000 RPM 3576 Normal
Top Fan Tray 8 >= 2000 RPM 3468 Normal
Top Fan Tray 9 >= 2000 RPM 3492 Normal
Bottom Fan Tray 1 >= 2000 RPM 0 Missing
Bottom Fan Tray 2 >= 2000 RPM 0 Missing
Bottom Fan Tray 3 >= 2000 RPM 0 Missing
Bottom Fan Tray 4 >= 2000 RPM 0 Missing
Bottom Fan Tray 5 >= 2000 RPM 0 Missing
Bottom Fan Tray 6 >= 2000 RPM 0 Missing
Bottom Fan Tray 7 >= 2000 RPM 0 Missing
Bottom Fan Tray 8 >= 2000 RPM 0 Missing
Bottom Fan Tray 9 >= 2000 RPM 0 Missing
+5V Input 4.850^ to 5.150^ VoltsDC 5.036 Informational
+3.3V Input 3.200^ to 3.400^ VoltsDC 3.298 Informational
Type <CR> to continue, Q<CR> to stop:
pop20two System Rev: 02.00 Sep. 02, 2000 23:40:57 GMT
MGX8850 Shelf Alarm: NONE
ENVIRONMENTAL ALARM STATE INFO ^Notification Disabled
Alarm Type Unit Threshold DataType Value State
---------------- ---- -------------- -------- ---------- -------------
+2.5V Input 2.425^ to 2.575^ VoltsDC 2.479 Informational
Calibration VDC 0x7e^ to 0x82^ Other 0x80 Informational