Specifications
7-83
Cisco MGX 8850 (PXM45) and MGX 8950 Software Configuration Guide
Release 3, Part Number 78-14788-01 Rev. C0, January 2004
Chapter 7 Switch Operating Procedures
Verifying PXM45 Disk Data
If no discrepancies are found on a card, the log file contains only the slot number, timestamp of the
verification task, and a message stating that no discrepancies were found, as shown in the following
example:
------------------ Information for Slot 5 ------------------
Start: 22/05/2002-10:31:19 - End: 22/05/2002-10:31:27
Verify DONE
TotalofDbs= 2, TotalofTbls= 15, #DbVerf=2, #TblVerf= 15
No Discrepancies found for slot 5
If discrepancies were found on a card, the log file contains the names of the databases and tables in which
the discrepancies were found, as shown in the following example:
------------------ Information for Slot 1 ------------------
Start: 20/04/2002-17:43:49 - End: 20/04/2002-17:43:57
Verify DONE
TotalofDbs= 4, TotalofTbls= 20, #DbVerf=4, #TblVerf= 20
=============================================================
dbInd: 2 - dbName: EmDiskDb
tblInd: 17 - tblName: LineTable
Record: 8 ActvChkSum: 0 StdbyChkSum: 549
=============================================================
dbInd: 2 - dbName: EmDiskDb
tblInd: 17 - tblName: LineTable
Record: 9 ActvChkSum: 0 StdbyChkSum: 549
===============================================================
Verification Slot Summary
Start: 20/04/2002-17:43:49 - End: 20/04/2002-17:43:57
Total Discrepancies Found: 2, Total Discrepancies Sync: 0
--------------------------------------------------------------
If the verification utility is run on a slot in which no card resides, the display will show that the slot was
invalid and has been skipped, and shown in the following example:
--------------------------------------------------------------
------------------ Information for Slot 2 ------------------
Start: 22/05/2002-10:31:10 - End: 22/05/2002-10:31:10
Verify SKIPPED - INV_SLOT
TotalofDbs= 0, TotalofTbls= 0, #DbVerf=0, #TblVerf= 0
No Discrepancies found for slot 2
--------------------------------------------------------------
--------------------------------------------------------------
If the card is in an unstable state, the display indicates that the verification utility has skipped that slot
because it is unstable, as shown in the following example.
------------------ Information for Slot 4 ------------------
Start: 20/04/2002-17:44:06 - End: 20/04/2002-17:44:06
Verify SKIPPED - UNSTABLE SLOT
TotalofDbs= 0, TotalofTbls= 0, #DbVerf=0, #TblVerf= 0
No Discrepancies found for slot 4
--------------------------------------------------------------