Specifications
7-38
Cisco MGX 8850 (PXM45) and MGX 8950 Software Configuration Guide
Release 3, Part Number 78-14788-01 Rev. C0, January 2004
Chapter 7 Switch Operating Procedures
Managing NCDP Clock Sources
Table 7-19 describes the objects displayed by the dspncdpports command.
Display An NCDP Port
Enter the dspncdpport <portid> command to display detailed information for a specified NCDP
signaling port. Replace <portid> with the port identifier in the format slot:bay.line:ifnum.
U1.8.PXM.a > dspncdpport 6:1.1:1
Network clock mode : disable
Ncdp Vc status : down
Network clock vpi : 0
Network clock vci : 34
Admin cost : 10
Service Category : sig
PCR : 250
SCR : 150
MBS : 100
Table 7-20 describes the objects displayed by the dspncdpport command.
Table 7-19 dspncdpports Command Objects
Parameter Description
PortID Port identifier in the format slot:bay.line:ifnum.
Table 7-1 describes these parameters.
Clock mode Displays whether NCDP is enabled or disabled on
each port.
Clock Vpi Displays the VPI of the signaling channel for each
port.
Clock Vci Displays the VCI of the signaling channel for
each port.
Admin Cost Displays the routing cost of the port.
Ncdp Vc Displays whether the Ncdp VC is up or down.
Table 7-20 dspncdpport Command Objects
Parameter Description
Clock mode Displays whether NCDP is enabled or disabled on
each port.
Ncdp Vc status Displays whether the Ncdp VC is up or down.
Network clock vpi Displays the VPI of the signaling channel for each
port.
Network clock vci Displays the VCI of the signaling channel for
each port.
Admin Cost Displays the routing cost of the port.
Service Category Displays the service category for the current
NCDP port.
PCR Displays the peak cell rate (PCR) for the port.