Specifications

9-77
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 9 Switch Operating Procedures
Verifying PXM Disk Data
If the verification utility is run on a slot in which no card resides, the display will show that the slot is
invalid and has been skipped as shown in the following example:
--------------------------------------------------------------
------------------ Information for Slot 2 ------------------
Start: 22/05/2002-10:31:10 - End: 22/05/2002-10:31:10
Verify SKIPPED - INV_SLOT
TotalofDbs= 0, TotalofTbls= 0, #DbVerf=0, #TblVerf= 0
No Discrepancies found for slot 2
--------------------------------------------------------------
--------------------------------------------------------------
If the card is in an unstable state, the display indicates that the verification utility skipped that slot
because it is unstable. The following example shows this:
------------------ Information for Slot 4 ------------------
Start: 20/04/2002-17:44:06 - End: 20/04/2002-17:44:06
Verify SKIPPED - UNSTABLE SLOT
TotalofDbs= 0, TotalofTbls= 0, #DbVerf=0, #TblVerf= 0
No Discrepancies found for slot 4
--------------------------------------------------------------
If a firmware upgrade did not finish (the commitrev command was not issued on the slot), the display
indicates that the verification utility skipped that slot because a REV_CHG is in progress. This is shown
in the following example:
------------------ Information for Slot 6 ------------------
Start: 20/04/2002-17:44:14 - End: 20/04/2002-17:44:14
Verify SKIPPED - REV_CHG
TotalofDbs= 0, TotalofTbls= 0, #DbVerf=0, #TblVerf= 0
No Discrepancies found for slot 6
--------------------------------------------------------------
If more than 20 discrepancies are found in a table or database, the utility terminates and the display
indicates that the slot is unstable. The display also lists the names of the tables and databases where the
discrepancies were found. The following example shows the display for an unstable slot with more that
20 discrepancies:
----------------- Information for Slot 9 ------------------
Start: 20/04/2002-17:44:54 - End: 20/04/2002-17:44:57
Verify SKIPPED - UNSTABLE SLOT
TotalofDbs= 2, TotalofTbls= 6, #DbVerf=0, #TblVerf= 0
=============================================================
dbInd: 1 - dbName: sm_mib_v21
tblInd: 5 - tblName: mib29
Record: 1782 ActvComdID: 0 StdbyComID: 7
=============================================================
dbInd: 1 - dbName: sm_mib_v21
tblInd: 5 - tblName: mib29
Record: 1783 ActvComdID: 0 StdbyComID: 7
=============================================================
dbInd: 1 - dbName: sm_mib_v21
tblInd: 5 - tblName: mib29
Record: 1784 ActvComdID: 0 StdbyComID: 7
=============================================================